ホーム > ブログ> Pipeline Filter Features Pipeline Filter Tips

Pipeline Filter Features Pipeline Filter Tips

May 18, 2024

The pipe filter is mainly composed of a pipe , a barrel, a filter basket, a flange, a flange cover, and a fastener. Installed in the pipeline can remove large solid impurities in the fluid, so that machinery and equipment (including compressors, pumps, etc.), instruments can work properly and operate, to stabilize the process, to ensure the role of safety in production. So, what is the working principle of the pipeline filter? What are the characteristics? How to use? Next, Xiao Bian answered everybody one by one.

Pipeline filter works

When the liquid enters the filter basket through the cylinder, solid foreign particles are trapped in the filter basket, and the clean fluid passes through the filter basket and exits through the filter outlet. When cleaning is needed, unscrew the bottom plug of the main pipe, drain the fluid, remove the flange cover, and then re-install it after cleaning. Therefore, the use of maintenance is extremely convenient.

Pipeline filter features

1, the design structure is simple.

2, anti-cleaning time is short, flow, pressure loss.

3, control system intelligent (PLC, PAC) control, high degree of automation.

4, the device can be connected with the central control system.

5, high-precision filtration, the water quality is stable.

6. The filter is used for life, without replacement.

7, long service life.

8, can be applied to different raw water quality and water requirements.

9, less wearing parts, no consumables, low operating costs, simple operation and management.

Pipeline filter tips

a: Manual control:

Rotate the manual/automatic selector switch to the manual position. See Figure 8. The motor and hydraulic control valve are energized, and the hydraulic control valve opens to begin draining. The selector switch rotates to the automatic position and enters the automatic state.

The manual control state is a means of checking whether the motor and the hydraulic control valve can work normally. If the manual control state does not properly discharge the automatic control state, it will not work normally.

b: Automatic control:

Rotate the manual/automatic selector switch to the automatic position, first set the filter time and the blowdown time timer. The lower nixie tube of the timer shows the setting value, and the upper nixie tube shows the timing value.

Timer setting method: press the position selection button, the first digit tube in the lower row flashes, use the increase key to adjust the value, adjust and then press the position selection key, the second digital tube flashes, use the increase key to adjust the value, analogy. Set the time, the digital tube will continue flashing for 8 seconds, after 8 seconds, the value will be stored in memory.

And power loss is not lost. After adjusting the value, press the start button to start timing. If the machine is powered off, the next time the power is turned on, the timer starts automatically and the time is set according to the set time.

Filtering time is divided into units up to 9999 minutes; sewage time is measured in seconds and the maximum time is 99.99 seconds. The machine is powered on, and the selector switch is used to enter the automatic state. The first step is to filter and the filter time timer starts timing. At the same time, the pressure difference switch also compares the actual pressure difference with the set pressure difference. If the set filtering time comes, the pressure difference If not, the machine will open the blowdown valve to clean the sewage. When the filtration time stops, the sewage time starts counting. When the blowdown time expires, the blowdown valve is closed, the cleaning sewage is stopped, and the blowdown time stops. The filtration time starts counting and enters the next cycle. If the set filtration time does not arrive and the pressure difference is reached, the machine will open the blowdown valve to clean the blowdown. The stop time of the filter time will start and the blowdown time will begin to time. When the blowdown time expires, the blowdown valve will be closed, the blowdown will be stopped, and the blowdown time will stop. The filter time starts and it circulates.

The above is the related content of the pipeline filter, I hope to help you. For more information on the filter, please continue to pay attention to this site information.

Filter brand pipeline color matching skills pipeline leakage storage skills

Uv Curing Screen Protector, UV Cured Screen Protector, UV Light Screen Protector, Uv Curing Film Sheets, UV Screen Protector

お問い合わせ

Author:

Ms. eleven

Eメール:

magic@magicmax.cc

Phone/WhatsApp:

+8613538497137

人気商品
Blog News
You may also like
Related Categories

この仕入先にメール

タイトル:
イーメール:
メッセージ:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

送信